{"id":31954,"date":"2019-05-02T19:12:52","date_gmt":"2019-05-02T17:12:52","guid":{"rendered":"https:\/\/www.sauter-controls.com\/produit\/pneumatic-sash-sensor\/"},"modified":"2019-05-23T13:40:10","modified_gmt":"2019-05-23T11:40:10","slug":"pneumatic-sash-sensor","status":"publish","type":"produit","link":"https:\/\/www.sauter-controls.com\/en\/produkt\/pneumatic-sash-sensor\/","title":{"rendered":"Pneumatic sash sensor"},"content":{"rendered":"<p>TUP 224 F9..<\/p>\n","protected":false},"template":"","categorieProduit":[605],"class_list":["post-31954","produit","type-produit","status-publish","hentry","categorie-produit-individual-room-controlsystems-vav"],"acf":{"image_produits_home":{"ID":49859,"id":49859,"title":"TUP 224 F901: Pneum. Weg-Transmitter","filename":"423045-1.jpg","filesize":34279,"url":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","link":"https:\/\/www.sauter-controls.com\/produkt\/pneum-weg-transmitter\/423045-1\/","alt":"","author":"5","description":"","caption":"","name":"423045-1","status":"inherit","uploaded_to":31363,"date":"2022-07-19 15:57:30","modified":"2022-07-19 15:59:16","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.sauter-controls.com\/wp-includes\/images\/media\/default.png","width":600,"height":1127,"sizes":{"thumbnail":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-160x300.jpg","medium-width":160,"medium-height":300,"medium_large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","medium_large-width":600,"medium_large-height":1127,"large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-545x1024.jpg","large-width":545,"large-height":1024,"1536x1536":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","1536x1536-width":600,"1536x1536-height":1127,"2048x2048":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","2048x2048-width":600,"2048x2048-height":1127,"sparkling-featured":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-600x410.jpg","sparkling-featured-width":600,"sparkling-featured-height":410,"sparkling-featured-fullwidth":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-600x624.jpg","sparkling-featured-fullwidth-width":600,"sparkling-featured-fullwidth-height":624,"tab-small":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-60x60.jpg","tab-small-width":60,"tab-small-height":60,"img-angebot":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-360x290.jpg","img-angebot-width":360,"img-angebot-height":290,"img-produit":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-290x333.jpg","img-produit-width":290,"img-produit-height":333,"img-fond":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-600x602.jpg","img-fond-width":600,"img-fond-height":602,"img-article":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-225x423.jpg","img-article-width":225,"img-article-height":423,"img-cadre":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-375x330.jpg","img-cadre-width":375,"img-cadre-height":330,"slider":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-426x800.jpg","slider-width":426,"slider-height":800,"img-prod-inno":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-480x240.jpg","img-prod-inno-width":480,"img-prod-inno-height":240,"img-rpoduit-interne":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-380x560.jpg","img-rpoduit-interne-width":380,"img-rpoduit-interne-height":560}},"image_produit_grand":{"ID":49859,"id":49859,"title":"TUP 224 F901: Pneum. Weg-Transmitter","filename":"423045-1.jpg","filesize":34279,"url":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","link":"https:\/\/www.sauter-controls.com\/produkt\/pneum-weg-transmitter\/423045-1\/","alt":"","author":"5","description":"","caption":"","name":"423045-1","status":"inherit","uploaded_to":31363,"date":"2022-07-19 15:57:30","modified":"2022-07-19 15:59:16","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.sauter-controls.com\/wp-includes\/images\/media\/default.png","width":600,"height":1127,"sizes":{"thumbnail":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-160x300.jpg","medium-width":160,"medium-height":300,"medium_large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","medium_large-width":600,"medium_large-height":1127,"large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-545x1024.jpg","large-width":545,"large-height":1024,"1536x1536":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","1536x1536-width":600,"1536x1536-height":1127,"2048x2048":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1.jpg","2048x2048-width":600,"2048x2048-height":1127,"sparkling-featured":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-600x410.jpg","sparkling-featured-width":600,"sparkling-featured-height":410,"sparkling-featured-fullwidth":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-600x624.jpg","sparkling-featured-fullwidth-width":600,"sparkling-featured-fullwidth-height":624,"tab-small":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-60x60.jpg","tab-small-width":60,"tab-small-height":60,"img-angebot":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-360x290.jpg","img-angebot-width":360,"img-angebot-height":290,"img-produit":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-290x333.jpg","img-produit-width":290,"img-produit-height":333,"img-fond":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-600x602.jpg","img-fond-width":600,"img-fond-height":602,"img-article":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-225x423.jpg","img-article-width":225,"img-article-height":423,"img-cadre":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-375x330.jpg","img-cadre-width":375,"img-cadre-height":330,"slider":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-426x800.jpg","slider-width":426,"slider-height":800,"img-prod-inno":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-480x240.jpg","img-prod-inno-width":480,"img-prod-inno-height":240,"img-rpoduit-interne":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423045-1-380x560.jpg","img-rpoduit-interne-width":380,"img-rpoduit-interne-height":560}},"title_":"Pneumatic sash sensor","reference":"TUP 224 F9..","description":"<b>How energy efficiency is improved<\/b><br>\nEnables the demand-led control of the air volume in laboratory fume cupboards.\n<br>\n<br><b>Areas of application<\/b><br>\nCreation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller.\n<br>\n<b><br>Properties<\/b><br>\n<ul><li>Continuous output signal is specified as command variable to the volume flow controller<\/li>\n<li>Installation preferably to be on counterweight of laboratory fume cupboard sash<\/li>\n<li>Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6)<\/li>\n<li>Compressed-air connections with Rp 1\/8\" female thread<\/li>\n<li>Long-term-stable stainless steel spring<\/li>\n<\/ul>\n<br><b>Technical description<\/b><br>\n<ul>\n  <li>Supply pressure 1.3 bar \u00b1 0.1<\/li>\n<li>Measuring ranges up to 2 m possible for free-standing fume cupboards <\/li>\n<li>Linearity 2%<\/li>\n<\/ul>\n","caracteristiques":"","id_langue":"3","id_pdm":"428160","id_3ma":"7ac40106-055d-0100-6015-190424162712","handbucher":false,"montagevorschriften":[{"titre_du_media":"TUP224F901","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/695201.pdf","type_de_media":"pdf","type_de_media_poids":"2 MB","indicateur_si_nouveau":[]}],"service-dokumentationen":false,"material-und-umweltdeklarationen":false,"prasentationen":false,"broschuren":[{"titre_du_media":"Pneumatic room pressure control","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/593443.pdf","type_de_media":"pdf","type_de_media_poids":"361 KB","indicateur_si_nouveau":[]}],"ubrige_dokumente":[{"titre_du_media":"incorporating clean rooms into a building management system","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/472556.pdf","type_de_media":"pdf","type_de_media_poids":"929 KB","indicateur_si_nouveau":[]}],"kurzbedienungsanleitungen":false,"ausschreibungstexte":false,"datenblatter":[{"titre_du_media":"TUP 224 F901: Pneumatic sash sensor","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/705731.PDF","type_de_media":"PDF","type_de_media_poids":"160 KB","indicateur_si_nouveau":[]}],"software":false,"white_papers":false,"videos":false,"bim":false,"typen":false,"number_id_pc":"67.520","pro_file":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Pneumatic sash sensor TUP 224 F9.. \u25ba SAUTER Controls<\/title>\n<meta name=\"description\" content=\"TUP 224 F9.. | How energy efficiency is improved Enables the demand-led control of the air volume in laboratory fume cupboards.  Areas of application Creation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller.  Properties Continuous output signal is specified as command variable to the volume flow controller Installation preferably to be on counterweight of laboratory fume cupboard sash Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Compressed-air connections with Rp 1\/8&quot; female thread Long-term-stable stainless steel spring  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Measuring ranges up to 2 m possible for free-standing fume cupboards  Linearity 2%\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pneumatic sash sensor TUP 224 F9.. \u25ba SAUTER Controls\" \/>\n<meta property=\"og:description\" content=\"TUP 224 F9.. | How energy efficiency is improved Enables the demand-led control of the air volume in laboratory fume cupboards.  Areas of application Creation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller.  Properties Continuous output signal is specified as command variable to the volume flow controller Installation preferably to be on counterweight of laboratory fume cupboard sash Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Compressed-air connections with Rp 1\/8&quot; female thread Long-term-stable stainless steel spring  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Measuring ranges up to 2 m possible for free-standing fume cupboards  Linearity 2%\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/\" \/>\n<meta property=\"og:site_name\" content=\"sauter-controls.com\" \/>\n<meta property=\"article:modified_time\" content=\"2019-05-23T11:40:10+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/\",\"url\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/\",\"name\":\"Pneumatic sash sensor TUP 224 F9.. \u25ba SAUTER Controls\",\"isPartOf\":{\"@id\":\"https:\/\/www.sauter-controls.com\/en\/#website\"},\"datePublished\":\"2019-05-02T17:12:52+00:00\",\"dateModified\":\"2019-05-23T11:40:10+00:00\",\"description\":\"TUP 224 F9.. | How energy efficiency is improved Enables the demand-led control of the air volume in laboratory fume cupboards. Areas of application Creation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller. Properties \u2022 Continuous output signal is specified as command variable to the volume flow controller \u2022 Installation preferably to be on counterweight of laboratory fume cupboard sash \u2022 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) \u2022 Compressed-air connections with Rp 1\/8\\\" female thread \u2022 Long-term-stable stainless steel spring Technical description \u2022 Supply pressure 1.3 bar \u00b1 0.1 \u2022 Measuring ranges up to 2 m possible for free-standing fume cupboards \u2022 Linearity 2%\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sauter-controls.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pneumatic sash sensor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sauter-controls.com\/en\/#website\",\"url\":\"https:\/\/www.sauter-controls.com\/en\/\",\"name\":\"sauter-controls.com\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sauter-controls.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pneumatic sash sensor TUP 224 F9.. \u25ba SAUTER Controls","description":"TUP 224 F9.. | How energy efficiency is improved Enables the demand-led control of the air volume in laboratory fume cupboards.  Areas of application Creation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller.  Properties Continuous output signal is specified as command variable to the volume flow controller Installation preferably to be on counterweight of laboratory fume cupboard sash Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Compressed-air connections with Rp 1\/8\" female thread Long-term-stable stainless steel spring  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Measuring ranges up to 2 m possible for free-standing fume cupboards  Linearity 2%","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/","og_locale":"en_US","og_type":"article","og_title":"Pneumatic sash sensor TUP 224 F9.. \u25ba SAUTER Controls","og_description":"TUP 224 F9.. | How energy efficiency is improved Enables the demand-led control of the air volume in laboratory fume cupboards.  Areas of application Creation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller.  Properties Continuous output signal is specified as command variable to the volume flow controller Installation preferably to be on counterweight of laboratory fume cupboard sash Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Compressed-air connections with Rp 1\/8\" female thread Long-term-stable stainless steel spring  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Measuring ranges up to 2 m possible for free-standing fume cupboards  Linearity 2%","og_url":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/","og_site_name":"sauter-controls.com","article_modified_time":"2019-05-23T11:40:10+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/","url":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/","name":"Pneumatic sash sensor TUP 224 F9.. \u25ba SAUTER Controls","isPartOf":{"@id":"https:\/\/www.sauter-controls.com\/en\/#website"},"datePublished":"2019-05-02T17:12:52+00:00","dateModified":"2019-05-23T11:40:10+00:00","description":"TUP 224 F9.. | How energy efficiency is improved Enables the demand-led control of the air volume in laboratory fume cupboards. Areas of application Creation of VAV systems for fume cupboards, can be used especially in potentially explosive areas in zone 1 II 2 G T6, in combination with the RLP 100 F123 pneumatic volume-flow controller. Properties \u2022 Continuous output signal is specified as command variable to the volume flow controller \u2022 Installation preferably to be on counterweight of laboratory fume cupboard sash \u2022 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) \u2022 Compressed-air connections with Rp 1\/8\" female thread \u2022 Long-term-stable stainless steel spring Technical description \u2022 Supply pressure 1.3 bar \u00b1 0.1 \u2022 Measuring ranges up to 2 m possible for free-standing fume cupboards \u2022 Linearity 2%","breadcrumb":{"@id":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-sash-sensor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sauter-controls.com\/en\/"},{"@type":"ListItem","position":2,"name":"Pneumatic sash sensor"}]},{"@type":"WebSite","@id":"https:\/\/www.sauter-controls.com\/en\/#website","url":"https:\/\/www.sauter-controls.com\/en\/","name":"sauter-controls.com","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sauter-controls.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/produits\/31954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/produits"}],"about":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/types\/produit"}],"wp:attachment":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/media?parent=31954"}],"wp:term":[{"taxonomy":"categorie-produit","embeddable":true,"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/categorieProduit?post=31954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}