{"id":31820,"date":"2019-05-02T19:07:02","date_gmt":"2019-05-02T17:07:02","guid":{"rendered":"https:\/\/www.sauter-controls.com\/produit\/pneumatic-volume-flow-controller\/"},"modified":"2019-05-23T13:37:52","modified_gmt":"2019-05-23T11:37:52","slug":"pneumatic-volume-flow-controller","status":"publish","type":"produit","link":"https:\/\/www.sauter-controls.com\/en\/produkt\/pneumatic-volume-flow-controller\/","title":{"rendered":"Pneumatic volume-flow controller"},"content":{"rendered":"<p>RLP 10<\/p>\n","protected":false},"template":"","categorieProduit":[605],"class_list":["post-31820","produit","type-produit","status-publish","hentry","categorie-produit-individual-room-controlsystems-vav"],"acf":{"image_produits_home":{"ID":49801,"id":49801,"title":"RLP 10: Pneumatische Volumenstromregler","filename":"423038-1.jpg","filesize":83579,"url":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","link":"https:\/\/www.sauter-controls.com\/produkt\/pneumatischer-volumenstromregler\/423038-1\/","alt":"","author":"5","description":"","caption":"","name":"423038-1","status":"inherit","uploaded_to":31223,"date":"2022-07-19 14:03:52","modified":"2022-07-19 14:04:01","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.sauter-controls.com\/wp-includes\/images\/media\/default.png","width":600,"height":539,"sizes":{"thumbnail":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-300x270.jpg","medium-width":300,"medium-height":270,"medium_large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","medium_large-width":600,"medium_large-height":539,"large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","large-width":600,"large-height":539,"1536x1536":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","1536x1536-width":600,"1536x1536-height":539,"2048x2048":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","2048x2048-width":600,"2048x2048-height":539,"sparkling-featured":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-600x410.jpg","sparkling-featured-width":600,"sparkling-featured-height":410,"sparkling-featured-fullwidth":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","sparkling-featured-fullwidth-width":600,"sparkling-featured-fullwidth-height":539,"tab-small":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-60x60.jpg","tab-small-width":60,"tab-small-height":60,"img-angebot":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-360x290.jpg","img-angebot-width":360,"img-angebot-height":290,"img-produit":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-290x333.jpg","img-produit-width":290,"img-produit-height":333,"img-fond":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","img-fond-width":600,"img-fond-height":539,"img-article":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-225x202.jpg","img-article-width":225,"img-article-height":202,"img-cadre":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-375x330.jpg","img-cadre-width":375,"img-cadre-height":330,"slider":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","slider-width":600,"slider-height":539,"img-prod-inno":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-480x240.jpg","img-prod-inno-width":480,"img-prod-inno-height":240,"img-rpoduit-interne":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-380x539.jpg","img-rpoduit-interne-width":380,"img-rpoduit-interne-height":539}},"image_produit_grand":{"ID":49801,"id":49801,"title":"RLP 10: Pneumatische Volumenstromregler","filename":"423038-1.jpg","filesize":83579,"url":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","link":"https:\/\/www.sauter-controls.com\/produkt\/pneumatischer-volumenstromregler\/423038-1\/","alt":"","author":"5","description":"","caption":"","name":"423038-1","status":"inherit","uploaded_to":31223,"date":"2022-07-19 14:03:52","modified":"2022-07-19 14:04:01","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.sauter-controls.com\/wp-includes\/images\/media\/default.png","width":600,"height":539,"sizes":{"thumbnail":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-300x270.jpg","medium-width":300,"medium-height":270,"medium_large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","medium_large-width":600,"medium_large-height":539,"large":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","large-width":600,"large-height":539,"1536x1536":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","1536x1536-width":600,"1536x1536-height":539,"2048x2048":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","2048x2048-width":600,"2048x2048-height":539,"sparkling-featured":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-600x410.jpg","sparkling-featured-width":600,"sparkling-featured-height":410,"sparkling-featured-fullwidth":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","sparkling-featured-fullwidth-width":600,"sparkling-featured-fullwidth-height":539,"tab-small":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-60x60.jpg","tab-small-width":60,"tab-small-height":60,"img-angebot":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-360x290.jpg","img-angebot-width":360,"img-angebot-height":290,"img-produit":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-290x333.jpg","img-produit-width":290,"img-produit-height":333,"img-fond":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","img-fond-width":600,"img-fond-height":539,"img-article":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-225x202.jpg","img-article-width":225,"img-article-height":202,"img-cadre":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-375x330.jpg","img-cadre-width":375,"img-cadre-height":330,"slider":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1.jpg","slider-width":600,"slider-height":539,"img-prod-inno":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-480x240.jpg","img-prod-inno-width":480,"img-prod-inno-height":240,"img-rpoduit-interne":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/2022\/07\/423038-1-380x539.jpg","img-rpoduit-interne-width":380,"img-rpoduit-interne-height":539}},"title_":"Pneumatic volume-flow controller","reference":"RLP 10","description":"<b>How energy efficiency is improved<\/b><br>\nFor demand-led control of the air volume in office rooms.\n<br>\n<br><b>Areas of application<\/b><br>\nControl of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas.\n<br>\n<b><br>Properties<\/b><br>\n<ul><li>Suitable for use in areas at risk of explosions in zone 1 II 2 G T6<\/li>\n<li>Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6)<\/li>\n<li>Control of constant, switchable or variable air volumes<\/li>\n<li>Static differential pressure sensor with large measuring range (10 to 250 Pa)<\/li>\n<li>Controller front panel is printed with circuit diagram for rapid identification of function <\/li>\n<li>Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 ) <\/li>\n<li>Compressed-air connections with Rp 1\/8\" female thread<\/li>\n<li>Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm)<\/li>\n<\/ul>\n<br><b>Technical description<\/b><br>\n<ul>\n  <li>Supply pressure 1.3 bar \u00b1 0.1<\/li>\n<li>Response sensitivity of sensor 0.5 Pa<\/li>\n<li>Linearity, square root extraction accuracy 2%<\/li>\n<li>One input for command variable<\/li>\n<li>Two outputs for:<\/li><ul>\n<li>actual value<\/li>\n<li>activation of damper drive<\/li><\/ul>\n<li>Two setpoint adjusters for maximum and minimum limiting of volume flow<\/li>\n<\/ul>\n","caracteristiques":"","id_langue":"3","id_pdm":"428153","id_3ma":"9fbc4ae6-85a0-0500-3984-190424162712","handbucher":false,"montagevorschriften":[{"titre_du_media":"MV RLP10F001, F905","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/1084163.pdf","type_de_media":"pdf","type_de_media_poids":"676 KB","indicateur_si_nouveau":[]}],"service-dokumentationen":[{"titre_du_media":"Pneum. Ger\u00e4te","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/444206.pdf","type_de_media":"pdf","type_de_media_poids":"1 MB","indicateur_si_nouveau":[]}],"material-und-umweltdeklarationen":false,"prasentationen":false,"broschuren":[{"titre_du_media":"Pneumatic room pressure control","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/593443.pdf","type_de_media":"pdf","type_de_media_poids":"361 KB","indicateur_si_nouveau":[]}],"ubrige_dokumente":[{"titre_du_media":"incorporating clean rooms into a building management system","adresse_du_media":"https:\/\/www.sauter-controls.com\/wp-content\/uploads\/ImportPDM\/472556.pdf","type_de_media":"pdf","type_de_media_poids":"929 KB","indicateur_si_nouveau":[]}],"kurzbedienungsanleitungen":false,"ausschreibungstexte":false,"datenblatter":false,"software":false,"white_papers":false,"videos":false,"bim":false,"typen":[{"reference":"RLP10F001","description":"Pn.volumeflow I-controllerB"}],"number_id_pc":"67.301","pro_file":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Pneumatic volume-flow controller RLP 10 \u25ba SAUTER Controls<\/title>\n<meta name=\"description\" content=\"RLP 10 | How energy efficiency is improved For demand-led control of the air volume in office rooms.  Areas of application Control of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas.  Properties Suitable for use in areas at risk of explosions in zone 1 II 2 G T6 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Control of constant, switchable or variable air volumes Static differential pressure sensor with large measuring range (10 to 250 Pa) Controller front panel is printed with circuit diagram for rapid identification of function  Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 )  Compressed-air connections with Rp 1\/8&quot; female thread Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm)  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Response sensitivity of sensor 0.5 Pa Linearity, square root extraction accuracy 2% One input for command variable Two outputs for: actual value activation of damper drive Two setpoint adjusters for maximum and minimum limiting of volume flow\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pneumatic volume-flow controller RLP 10 \u25ba SAUTER Controls\" \/>\n<meta property=\"og:description\" content=\"RLP 10 | How energy efficiency is improved For demand-led control of the air volume in office rooms.  Areas of application Control of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas.  Properties Suitable for use in areas at risk of explosions in zone 1 II 2 G T6 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Control of constant, switchable or variable air volumes Static differential pressure sensor with large measuring range (10 to 250 Pa) Controller front panel is printed with circuit diagram for rapid identification of function  Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 )  Compressed-air connections with Rp 1\/8&quot; female thread Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm)  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Response sensitivity of sensor 0.5 Pa Linearity, square root extraction accuracy 2% One input for command variable Two outputs for: actual value activation of damper drive Two setpoint adjusters for maximum and minimum limiting of volume flow\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/\" \/>\n<meta property=\"og:site_name\" content=\"sauter-controls.com\" \/>\n<meta property=\"article:modified_time\" content=\"2019-05-23T11:37:52+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/\",\"url\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/\",\"name\":\"Pneumatic volume-flow controller RLP 10 \u25ba SAUTER Controls\",\"isPartOf\":{\"@id\":\"https:\/\/www.sauter-controls.com\/en\/#website\"},\"datePublished\":\"2019-05-02T17:07:02+00:00\",\"dateModified\":\"2019-05-23T11:37:52+00:00\",\"description\":\"RLP 10 | How energy efficiency is improved For demand-led control of the air volume in office rooms. Areas of application Control of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas. Properties \u2022 Suitable for use in areas at risk of explosions in zone 1 II 2 G T6 \u2022 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) \u2022 Control of constant, switchable or variable air volumes \u2022 Static differential pressure sensor with large measuring range (10 to 250 Pa) \u2022 Controller front panel is printed with circuit diagram for rapid identification of function \u2022 Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 ) \u2022 Compressed-air connections with Rp 1\/8\\\" female thread \u2022 Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm) Technical description \u2022 Supply pressure 1.3 bar \u00b1 0.1 \u2022 Response sensitivity of sensor 0.5 Pa \u2022 Linearity, square root extraction accuracy 2% \u2022 One input for command variable \u2022 Two outputs for: \u2022 actual value \u2022 activation of damper drive \u2022 Two setpoint adjusters for maximum and minimum limiting of volume flow\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sauter-controls.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pneumatic volume-flow controller\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sauter-controls.com\/en\/#website\",\"url\":\"https:\/\/www.sauter-controls.com\/en\/\",\"name\":\"sauter-controls.com\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sauter-controls.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pneumatic volume-flow controller RLP 10 \u25ba SAUTER Controls","description":"RLP 10 | How energy efficiency is improved For demand-led control of the air volume in office rooms.  Areas of application Control of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas.  Properties Suitable for use in areas at risk of explosions in zone 1 II 2 G T6 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Control of constant, switchable or variable air volumes Static differential pressure sensor with large measuring range (10 to 250 Pa) Controller front panel is printed with circuit diagram for rapid identification of function  Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 )  Compressed-air connections with Rp 1\/8\" female thread Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm)  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Response sensitivity of sensor 0.5 Pa Linearity, square root extraction accuracy 2% One input for command variable Two outputs for: actual value activation of damper drive Two setpoint adjusters for maximum and minimum limiting of volume flow","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/","og_locale":"en_US","og_type":"article","og_title":"Pneumatic volume-flow controller RLP 10 \u25ba SAUTER Controls","og_description":"RLP 10 | How energy efficiency is improved For demand-led control of the air volume in office rooms.  Areas of application Control of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas.  Properties Suitable for use in areas at risk of explosions in zone 1 II 2 G T6 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) Control of constant, switchable or variable air volumes Static differential pressure sensor with large measuring range (10 to 250 Pa) Controller front panel is printed with circuit diagram for rapid identification of function  Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 )  Compressed-air connections with Rp 1\/8\" female thread Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm)  Technical description   Supply pressure 1.3 bar \u00b1 0.1 Response sensitivity of sensor 0.5 Pa Linearity, square root extraction accuracy 2% One input for command variable Two outputs for: actual value activation of damper drive Two setpoint adjusters for maximum and minimum limiting of volume flow","og_url":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/","og_site_name":"sauter-controls.com","article_modified_time":"2019-05-23T11:37:52+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/","url":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/","name":"Pneumatic volume-flow controller RLP 10 \u25ba SAUTER Controls","isPartOf":{"@id":"https:\/\/www.sauter-controls.com\/en\/#website"},"datePublished":"2019-05-02T17:07:02+00:00","dateModified":"2019-05-23T11:37:52+00:00","description":"RLP 10 | How energy efficiency is improved For demand-led control of the air volume in office rooms. Areas of application Control of the supply and exhaust air of individual rooms or duct pressures. Can be used in potentially explosive areas. Properties \u2022 Suitable for use in areas at risk of explosions in zone 1 II 2 G T6 \u2022 Conformity tested as per EN 13463-1 and EN 1127-1 (Ex zone 1 II 2 G T6) \u2022 Control of constant, switchable or variable air volumes \u2022 Static differential pressure sensor with large measuring range (10 to 250 Pa) \u2022 Controller front panel is printed with circuit diagram for rapid identification of function \u2022 Thermoplastic housing suitable for wall or top-hat rail mounting (rail EN 60715 ) \u2022 Compressed-air connections with Rp 1\/8\" female thread \u2022 Low-pressure connections in form of stepped nipples for flexible plastic hose (internal \u00d8 4 and 6 mm) Technical description \u2022 Supply pressure 1.3 bar \u00b1 0.1 \u2022 Response sensitivity of sensor 0.5 Pa \u2022 Linearity, square root extraction accuracy 2% \u2022 One input for command variable \u2022 Two outputs for: \u2022 actual value \u2022 activation of damper drive \u2022 Two setpoint adjusters for maximum and minimum limiting of volume flow","breadcrumb":{"@id":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sauter-controls.com\/en\/product\/pneumatic-volume-flow-controller\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sauter-controls.com\/en\/"},{"@type":"ListItem","position":2,"name":"Pneumatic volume-flow controller"}]},{"@type":"WebSite","@id":"https:\/\/www.sauter-controls.com\/en\/#website","url":"https:\/\/www.sauter-controls.com\/en\/","name":"sauter-controls.com","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sauter-controls.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/produits\/31820","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/produits"}],"about":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/types\/produit"}],"wp:attachment":[{"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/media?parent=31820"}],"wp:term":[{"taxonomy":"categorie-produit","embeddable":true,"href":"https:\/\/www.sauter-controls.com\/en\/wp-json\/wp\/v2\/categorieProduit?post=31820"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}